Welcome to Jiangsu Huachen Transformer Co., Ltd.

PRODUCTS

Current location:Home - Products - Dry-type Power Transformer
Oil-immersed Power Transformer Dry-type Power Transformer Amorphous Alloy Power Transformer Coating Coil Power Transformer Transformer Substation Spare Parts
  • 33-38kV Dry-type Power Transformer
  • 33-38kV Dry-type Power Transformer
  • 33-38kV Dry-type Power Transformer

33-38kV Dry-type Power Transformer

SC (B) 10 epoxy resin cast dry-type transformer is manufactured according to standard of Dry-type Power Transformer, characterized with low performance loss, good energy saving effect, economic operation and no maintenance.

Hotline

+86 13624197312

60 seconds of manual response

Give technical advice within 30 minutes

24-hour free design

Product description

Product usage


SC (B) 10 epoxy resin cast dry-type transformer is manufactured according to standard of Dry-type Power Transformer, characterized with low performance loss, good energy saving effect, economic operation and no maintenance. In addition to high process structure metal, short-circuit resistance and lightning impulse level, it is still characterized with flame retardant, damp-proof, dust-proof and low noise, which can be connected to load center. It is widely used in high-rise buildings, airport, station, wharf, power plant, transformer substation, etc., especially applicable to be used in places with high fire protection requirements for flammable and combustible materials.

Standard transformer produced by the Company has no case, with the protection level of IP00, and case with the protection level of IP20 and IP23 can be provided as required by clients. Housing is made of such materials as common steel plate, corrosion resistant plate and aluminum alloy and then treated with acid pickling, phosphorization and plastics spraying according to the requirements of clients. Temperature control indicator and load recorder are installed on the low-tension side of the housing, convenient for observation and safe and reliable.


Product overview


Performance index of dry-type transformer produced by the Company meets various standards and it is demonstrated by users to have reliable operation and reach the national advanced level. This series of products are manufactured by using advanced foreign technology and design drawings and technical documents are complete, accurate and clear. The Company has advanced production equipment, stable manufacturing process and complete testing methods to provide solid guarantee for producing high-quality products.


Performance parameters


1. See the table for main performance parameters of SC (B) 10

2. Number of phases: 3-phase

3. Frequency: 50Hz

4. Insulation endurance class: Class F

5. Average temperature rise of winding: ≤100K

6. Magnitude of partial discharge: <5pc


Main performance parameters for SC (B) 10 33~38.5KV voltage regulating power transformer without excitation

Model

Connection symbol

Voltage combination (KV)

No-load loss (W)

Load loss (W)

No-load current (%)

Short circuit impedance (%)

High- voltage

Tapping range

Low-voltage

SC10-800

Dyn11

Yd11

Yyn0

33~38.5

±5%

±2×2.5%

3.5

6

6.3

10

10.5

11

2200

9400

1.1

6.0

SC10-1000

2610

10800

1.1

SC10-1250

3060

11900

1.0

SC10-1500

3600

15400

1.0

SC10-2000

4130

18200

0.9

7.0

SC10-2500

4750

21800

0.9

SC10-3150

5880

24500

0.8

8.0

SC10-4000

6860

29400

0.8

SC10-5000

8180

34960

0.7

SC10-6300

9680

40800

0.7

SC10-8000

Dyn11

Yd11

YNd11

11000

46060

0.6

9.0

SC10-10000

6

6.3

10.5

11

12660

56500

0.6

SC10-12500

15400

64600

0.5

SC10-16000

18900

76000

0.5

SC10-20000

22400

85500

0.4

10.0


Insulation level

Voltage classes

KV

Maximum running voltage

KV (effective value)

Rated short-time power frequency withstand voltage

KV (effective value)/1 minute

Rated lightning impulse withstand voltage

kV (peak value)

Full wave

Clipped wave

0.4

0.46

5

75

85

10

12

35

75

20

24

50

125

35

42

70

170

Order online

If you are interested in our products, or if we have anything to help you, you can always call our national customer service number:+86 13624197312

In order to serve you better and faster, please fill in the relevant information carefully, we will be happy to serve you!

33-38kV Dry-type Power Transformer

Product usage


SC (B) 10 epoxy resin cast dry-type transformer is manufactured according to standard of Dry-type Power Transformer, characterized with low performance loss, good energy saving effect, economic operation and no maintenance. In addition to high process structure metal, short-circuit resistance and lightning impulse level, it is still characterized with flame retardant, damp-proof, dust-proof and low noise, which can be connected to load center. It is widely used in high-rise buildings, airport, station, wharf, power plant, transformer substation, etc., especially applicable to be used in places with high fire protection requirements for flammable and combustible materials.

Standard transformer produced by the Company has no case, with the protection level of IP00, and case with the protection level of IP20 and IP23 can be provided as required by clients. Housing is made of such materials as common steel plate, corrosion resistant plate and aluminum alloy and then treated with acid pickling, phosphorization and plastics spraying according to the requirements of clients. Temperature control indicator and load recorder are installed on the low-tension side of the housing, convenient for observation and safe and reliable.


Product overview


Performance index of dry-type transformer produced by the Company meets various standards and it is demonstrated by users to have reliable operation and reach the national advanced level. This series of products are manufactured by using advanced foreign technology and design drawings and technical documents are complete, accurate and clear. The Company has advanced production equipment, stable manufacturing process and complete testing methods to provide solid guarantee for producing high-quality products.


Performance parameters


1. See the table for main performance parameters of SC (B) 10

2. Number of phases: 3-phase

3. Frequency: 50Hz

4. Insulation endurance class: Class F

5. Average temperature rise of winding: ≤100K

6. Magnitude of partial discharge: <5pc


Main performance parameters for SC (B) 10 33~38.5KV voltage regulating power transformer without excitation

Model

Connection symbol

Voltage combination (KV)

No-load loss (W)

Load loss (W)

No-load current (%)

Short circuit impedance (%)

High- voltage

Tapping range

Low-voltage

SC10-800

Dyn11

Yd11

Yyn0

33~38.5

±5%

±2×2.5%

3.5

6

6.3

10

10.5

11

2200

9400

1.1

6.0

SC10-1000

2610

10800

1.1

SC10-1250

3060

11900

1.0

SC10-1500

3600

15400

1.0

SC10-2000

4130

18200

0.9

7.0

SC10-2500

4750

21800

0.9

SC10-3150

5880

24500

0.8

8.0

SC10-4000

6860

29400

0.8

SC10-5000

8180

34960

0.7

SC10-6300

9680

40800

0.7

SC10-8000

Dyn11

Yd11

YNd11

11000

46060

0.6

9.0

SC10-10000

6

6.3

10.5

11

12660

56500

0.6

SC10-12500

15400

64600

0.5

SC10-16000

18900

76000

0.5

SC10-20000

22400

85500

0.4

10.0


Insulation level

Voltage classes

KV

Maximum running voltage

KV (effective value)

Rated short-time power frequency withstand voltage

KV (effective value)/1 minute

Rated lightning impulse withstand voltage

kV (peak value)

Full wave

Clipped wave

0.4

0.46

5

75

85

10

12

35

75

20

24

50

125

35

42

70

170

Copyights © 2019 All Rights Reserved Jiangsu Huachen Transformer Co., Ltd.